CVE-2019-25678
EUVD-2019-2009105.04.2026, 21:16
C4G Basic Laboratory Information System 3.4 contains multiple SQL injection vulnerabilities that allow unauthenticated attackers to execute arbitrary SQL commands by injecting malicious code through the site parameter. Attackers can send GET requests to the users_select.php endpoint with crafted SQL payloads to extract sensitive database information including patient records and system credentials.
Affected Products (NVD)
| Vendor | Product | Version |
|---|---|---|
| gatech | computing_for_good\'s_basic_laboratory_information_system | 𝑥 ≤ 3.4 |
𝑥
= Vulnerable software versions
Common Weakness Enumeration
- CWE-306 - Missing Authentication for Critical FunctionThe product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')The software constructs all or part of an SQL command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended SQL command when it is sent to a downstream component.