Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.Enginsight
Vendor | Product | Version |
---|---|---|
crestron | am-100_firmware | 1.6.0.2 |
crestron | am-101_firmware | 2.7.0.2 |
𝑥
= Vulnerable software versions
Common Weakness Enumeration
- CWE-522 - Insufficiently Protected CredentialsThe product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval.
- CWE-798 - Use of Hard-coded CredentialsThe software contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.