CVE-2020-12149

EUVD-2020-4464
The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0.
OS Command Injection
ProviderTypeBase ScoreAtk. VectorAtk. ComplexityPriv. RequiredVector
NISTPrimary
6.8 MEDIUM
NETWORK
LOW
HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H
Silver PeakCNA
6.8 MEDIUM
NETWORK
LOW
HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H
Base Score
CVSS 3.x
EPSS Score
Percentile: 58%
Affected Products (NVD)
VendorProductVersion
arubanetworksedgeconnect_enterprise
8.1 ≤
𝑥
< 8.1.9.15
arubanetworksedgeconnect_enterprise
8.3.0 ≤
𝑥
< 8.3.0.8
arubanetworksedgeconnect_enterprise
8.3.1 ≤
𝑥
< 8.3.1.2
arubanetworksedgeconnect_enterprise
9.0 ≤
𝑥
< 9.0.2.0
𝑥
= Vulnerable software versions