CVE-2021-34606

A vulnerability exists in XINJE XD/E Series PLC Program Tool in versions up to v3.5.1 that can allow an authenticated, local attacker to load a malicious DLL. Local access is required to successfully exploit this vulnerability. This means the potential attacker must have access to the system and sufficient file-write privileges. If exploited, the attacker could place a malicious DLL file on the system, that when running XINJE XD/E Series PLC Program Tool will allow the attacker to execute arbitrary code with the privileges of another user's account.
ProviderTypeBase ScoreAtk. VectorAtk. ComplexityPriv. RequiredVector
NISTNIST
7.3 HIGH
LOCAL
LOW
LOW
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
CERTVDECNA
7.3 HIGH
LOCAL
LOW
LOW
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
CVEADP
---
---