CVE-2022-1118

EUVD-2022-24461
Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited
ProviderTypeBase ScoreAtk. VectorAtk. ComplexityPriv. RequiredVector
NISTPrimary
8.6 HIGH
LOCAL
LOW
NONE
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
icscertCNA
8.6 HIGH
LOCAL
LOW
NONE
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
Base Score
CVSS 3.x
EPSS Score
Percentile: 97%
Affected Products (NVD)
VendorProductVersion
rockwellautomationconnected_component_workbench
𝑥
≤ 13.00.00
rockwellautomationisagraf_workbench
6.0 ≤
𝑥
≤ 6.6.9
rockwellautomationsafety_instrumented_systems_workstation
𝑥
≤ 1.2
𝑥
= Vulnerable software versions