CVE-2022-4608

A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.
ProviderTypeBase ScoreAtk. VectorAtk. ComplexityPriv. RequiredVector
NISTNIST
7.5 HIGH
NETWORK
LOW
NONE
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Hitachi EnergyCNA
7.5 HIGH
NETWORK
LOW
NONE
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVEADP
---
---
CISA-ADPADP
---
---
Base Score
CVSS 3.x
EPSS Score
Percentile: 16%
VendorProductVersion
hitachienergyrtu500_firmware
13.3.1
hitachienergyrtu500_firmware
13.3.2
hitachienergyrtu500_firmware
13.3.3
hitachienergyrtu500_firmware
13.4.1
𝑥
= Vulnerable software versions